GENERATOR HYDROGEN PURITY ANALYZER

RS-301ON Hydrogen Purity Analyzer

Temperature-compensated thermal conductivity•Protective hydrogen sampling system•Automatic drainage and safety bypass•Ex d IIC T6 Gb

Measurement rangesCO₂ in air / CO₂ in H₂: 0–100%; H₂ in air: 90–100%

Accuracy±2% F.S

Factory 4–20 mA mappingH₂ in air: 90–100%; max load 800 Ω

Sample flow / pressure0.5 SCFH / ≤0.1 MPa

Power supplyAC 90–265 V, 50 Hz; 35 W

Explosion protectionEx d IIC T6 Gb

HOW THE PRODUCT WORKS

Continuous hydrogen purity analysis for hydrogen-cooled generator sets

Online hydrogen purity monitoring for hydrogen-cooled generators

The RS-301ON Hydrogen Purity Analyzer is designed for hydrogen-cooled generator sets. It determines gas content using the thermal conductivity principle, with a temperature-compensated thermal-conductivity cell intended to support stable, accurate monitoring as operating temperature varies.

Sampling system designed for continuous operation

The analyzer is supplied with a hydrogen sampling system that filters oil and moisture from the sample gas to help protect the transmitter during continuous monitoring. The product information also describes a precise sampling arrangement for on-site calibration, automatic drainage, and a safety bypass function. These features support routine operation and service access in generator applications.

Measurement ranges for generator gas mixtures

The published ranges cover CO₂ in air from 0–100%, CO₂ in H₂ from 0–100%, and H₂ in air from 90–100%. The factory 4–20 mA output is configured for H₂ in air over 90–100%, with a maximum load of 800 Ω. Confirm the required gas-mixture mode and output mapping for your generator and gas-replacement procedure.

Plan the installation around sample conditions

The specified sample flow is 0.5 SCFH and the sampling pressure is up to 0.1 MPa. The analyzer accepts AC 90–265 V at 50 Hz, with 35 W power consumption. Its published explosion-protection marking is Ex d IIC T6 Gb. Confirm site classification, sample tubing, interfaces, and applicable certificates as part of project engineering.

For a quotation or configuration review, provide the generator model, gas mixture and measurement mode, sample pressure and flow, power supply, required outputs, installation area classification, and commissioning requirements. This helps configure an online hydrogen purity analyzer for hydrogen-cooled generator operation.

Key product features

Thermal-conductivity measurement

Uses the thermal conductivity principle to measure gas content, with a temperature-compensated cell for stable monitoring.

Three generator-gas measurement ranges

Measures CO₂ in air, CO₂ in H₂, and H₂ in air in the published ranges; confirm the target mixture and measurement mode for your operating procedure.

Protective sample conditioning

The accompanying sampling device is designed to filter oil and moisture from hydrogen samples to help protect the transmitter during continuous service.

On-site calibration support

The precise sampling arrangement is described as facilitating field calibration; confirm calibration procedure and required gases with the supplier.

Automatic drainage and safety bypass

Published features include automatic drainage and a safety bypass to support site operation and maintenance.

Generator-focused configuration

Developed for hydrogen-cooled generator requirements; review sample conditions, output mapping, and hazardous-area requirements for your installation.

APPLICATIONS

Typical applications

Hydrogen-cooled generator monitoring

Continuously monitor hydrogen purity and gas composition in hydrogen-cooled power generators.

Hydrogen and carbon-dioxide gas replacement

Use the listed H₂-in-air, CO₂-in-air, and CO₂-in-H₂ ranges to support generator gas replacement monitoring; confirm procedural setpoints for the unit.

Power-plant gas analysis systems

Integrate analyzer readings and alarm relay signals into generator monitoring and plant instrumentation, subject to interface review.

RS-301ON Hydrogen Purity Analyzer technical specifications and integration requirements

ParameterSpecification
Measurement principleThermal conductivity with temperature-compensated cell
CO₂ in air range0–100%
CO₂ in H₂ range0–100%
H₂ in air range90–100%
Accuracy±2% F.S
Analog output4–20 mA; factory setting corresponds to H₂ in air at 90–100%; maximum load 800 Ω
Alarm relayContact current: 3 A
Sample flow rate0.5 SCFH
Sampling pressure≤0.1 MPa
Input voltageAC 90–265 V, 50 Hz
Power consumption35 W
Explosion-proof markingEx d IIC T6 Gb
Dimensions (L × W × H)800 × 400 × 1660 mm
Sampling systemSample conditioning to filter oil and moisture; automatic drainage and safety bypass stated by manufacturer

Confirm the measuring range, output, power supply, and process conditions for your application when requesting a quotation.

What to include in your inquiry

For a project-specific RS-301ON Hydrogen Purity Analyzer quotation and application review, share your target measurement range, gas composition, operating temperature and humidity, pressure, installation method, required signal output, and project location. This helps our team assess the right configuration for your hydrogen monitoring or gas analysis system.

Send your application details

FAQ

Frequently asked questions about RS-301ON Hydrogen Purity Analyzer selection and applications

Find guidance on RS-301ON Hydrogen Purity Analyzer measuring range, installation, operating conditions, and integration with hydrogen monitoring systems.

01

What gas mixtures can the RS-301ON measure?

The published ranges are CO₂ in air at 0–100%, CO₂ in H₂ at 0–100%, and H₂ in air at 90–100%. Confirm which measurement mode is required for your generator and gas-replacement procedure.

02

What does the 4–20 mA output represent?

The factory setting maps the 4–20 mA output to H₂ in air from 90–100%; maximum load is 800 Ω. Confirm the requested mapping before ordering.

03

How does the sampling system protect the analyzer?

The product information describes sample conditioning that filters oil and moisture from hydrogen to help protect the transmitter. It also lists automatic drainage and a safety bypass.

04

What sample conditions are specified?

The published sample flow is 0.5 SCFH and sampling pressure is ≤0.1 MPa. Confirm actual site pressure, tubing, and sample requirements with the technical team.

05

What power and hazardous-area rating are listed?

The listed supply is AC 90–265 V, 50 Hz, with 35 W consumption; the explosion-proof marking is Ex d IIC T6 Gb. Verify the required certificates and site classification.

06

What details should I send for a quotation?

Share the generator model, gas mixtures and measurement mode, sampling pressure and flow, required output mapping, alarm integration, power supply, installation area classification, and commissioning needs.

Discuss RS-301ON Hydrogen Purity Analyzer for your application

Send your operating conditions and project requirements for a technical review and quotation.

Contact the Sales Team