Customizable wide measuring range
Select 0–2%, 0–5%, 0–10% or 0–100% Vol according to the target hydrogen concentration and process.
ONLINE HYDROGEN ANALYZER
Customizable wide-range measurement•Thermal conductivity sensing•Temperature and pressure compensation•Local display
Measuring range0–2 / 5 / 10 / 100% Vol (customizable)
Maximum allowable error+0.1% Vol (<5% Vol); ±2% F.S. (>5% Vol)
Resolution0.01% Vol
Response time≤30 s
OutputsRS-485; 4–20 mA; 2 alarm relays
ProtectionEx db IIC T6 Gb; IP65
HOW THE PRODUCT WORKS
The RD330 Online Hydrogen Analyzer is an industrial instrument for continuous hydrogen concentration monitoring. It uses a high-precision thermal conductivity sensor and offers configurable measuring ranges of 0–2%, 0–5%, 0–10% or 0–100% Vol. Temperature and pressure compensation support measurement stability across process conditions, while the local display provides an on-site reading.
For integration with plant control and alarm systems, the RD330 provides 4–20 mA and RS-485 outputs, plus two configurable relay alarm outputs. Its sample pretreatment inlet is specified for 0.1–10 MPa, while pressure at the sensing unit is below 0.1 MPa. The analyzer is designed for wall mounting and is specified with Ex db IIC T6 Gb explosion-proof marking and IP65 protection.
For a project review, share the required hydrogen range, gas composition, sample pressure, pretreatment needs, power supply option, control-system interface and alarm set points. The measurement error differs by concentration range, so include the expected operating range when requesting a quotation. This information helps size an online hydrogen concentration analyzer for the target process range and interfaces.
Select 0–2%, 0–5%, 0–10% or 0–100% Vol according to the target hydrogen concentration and process.
A high-precision thermal conductivity sensor measures hydrogen concentration for online monitoring.
The listed maximum error is +0.1% Vol below 5% Vol and ±2% F.S. above 5% Vol; confirm the expected operating range during selection.
Built-in temperature compensation and atmospheric-pressure compensation support measurement accuracy under changing conditions.
An LCD provides local readings; RS-485, 4–20 mA and two configurable relay outputs support connection to control and alarm systems.
The wall-mounted analyzer is specified with Ex db IIC T6 Gb marking and IP65 protection. Confirm project certification and installation requirements.
APPLICATIONS
Monitor hydrogen concentration in electrolyzer and production process streams.
Support online concentration monitoring in industrial gas blending systems.
Monitor hydrogen production processes and related process gas streams.
Provide online hydrogen measurement for fuel-cell testing and production systems.
Integrate hydrogen concentration monitoring into energy-storage process and safety systems.
Review the analyzer for hydrogen monitoring in industrial metallurgy and petrochemical applications.
| Parameter | Specification |
|---|---|
| Model | RD330 |
| Measured gas | Hydrogen (H₂) |
| Detection principle | Thermal conductivity |
| Measuring range | 0–2%, 0–5%, 0–10% or 0–100% Vol; range customizable |
| Maximum allowable error | +0.1% Vol at <5% Vol; ±2% F.S. at >5% Vol |
| Resolution | 0.01% Vol |
| Response time | ≤30 s |
| Sample pressure | Pretreatment system inlet: 0.1–10 MPa; sensing unit: <0.1 MPa |
| Output mode | RS-485 bus; 4–20 mA, three-wire |
| Relay output | 2 alarm outputs; alarm points configurable |
| Power consumption | 40 W at 24 VDC; 50 W at 220 VAC |
| Power supply | 24 ±2 VDC or 220 ±22 VAC |
| Operating temperature | −10 to +40 °C |
| Operating humidity | ≤90% RH |
| Explosion-proof marking | Ex db IIC T6 Gb |
| Protection rating | IP65 |
| Installation | Wall-mounted |
| Dimensions | 646 × 450 × 198 mm (L × W × H) |
Confirm the measuring range, output, power supply, and process conditions for your application when requesting a quotation.
For a project-specific RD330 Online Hydrogen Analyzer quotation and application review, share your target measurement range, gas composition, operating temperature and humidity, pressure, installation method, required signal output, and project location. This helps our team assess the right configuration for your hydrogen monitoring or gas analysis system.
Send your application detailsFAQ
Find guidance on RD330 Online Hydrogen Analyzer measuring range, installation, operating conditions, and integration with hydrogen monitoring systems.
The listed options are 0–2%, 0–5%, 0–10% and 0–100% Vol, with ranges customizable for the application.
It uses a high-precision thermal conductivity sensor with temperature and pressure compensation.
The reference lists +0.1% Vol below 5% Vol and ±2% F.S. above 5% Vol. Confirm the expected operating range and required specification for your project.
The analyzer lists RS-485, three-wire 4–20 mA and two configurable relay alarm outputs.
The pretreatment inlet pressure is listed as 0.1–10 MPa and sensing-unit pressure below 0.1 MPa. Confirm sample conditioning and whether 24 VDC or 220 VAC is required.
Share the target range, gas composition, sample pressure, pretreatment needs, power option, required output, alarm points, installation location and project application.
Send your operating conditions and project requirements for a technical review and quotation.
Contact the Sales Team