Portable Hydrogen Leak Detector product image

PORTABLE HYDROGEN LEAK DETECTOR

Portable Hydrogen Leak Detector

Dual sensors and dual ranges•Automatic range switching•Pump sampling•Audible and visual alarms

Measuring ranges0–1000 ppm / 0.1–4% Vol

Measurement methodPump suction, 200 mL/min

Response time<2 s

Resolution1 ppm

Measurement error30% (ppm range); ±5% F.S. (vol% range)

Explosion-proof markingEx ib IIC T3 Gb

HOW THE PRODUCT WORKS

Portable dual-range hydrogen leak detection for field inspections

The NA-1⁺ Portable Hydrogen Leak Detector is a handheld instrument for locating hydrogen leaks during field inspections. Its dual-sensor design automatically switches between a trace-gas range of 0–1000 ppm and a higher range of 0.1–4% Vol, helping operators assess both low-level leaks and higher concentrations with one portable detector.

The instrument uses pump suction at a specified flow rate of 200 mL/min. It provides a digital reading, stores measurement parameters and triggers an alarm when the measured concentration reaches a preset limit. Typical applications include leak checks on hydrogen-cooled generators, hydrogen production stations and hydrogen transmission pipelines.

Field setup and safety review

Before requesting a quotation, share the expected concentration range, sampling access, site classification, application and operating conditions. The reference lists explosion-proof marking Ex ib IIC T3 Gb; confirm the instrument marking, certificate scope and suitability against the hazardous-area classification and local requirements for each project.

These checks help select a portable hydrogen leak detector for field inspection in industrial and energy applications.

Key product features

Automatic dual-range detection

Dual sensors switch automatically between 0–1000 ppm trace detection and the 0.1–4% Vol range.

Pump-suction sampling

A specified sample flow of 200 mL/min supports active gas sampling during leak inspections.

Fast response and practical measurement tools

The reference specifies response below 2 seconds and includes automatic zero correction, peak detection, data hold and fast zero return.

Preset alarms and clear status indication

A segment LCD displays readings; threshold LEDs indicate 10 ppm, 100 ppm, 1000 ppm and 1% Vol. Sound and light alarms can be manually silenced.

Portable rechargeable operation

The lithium-ion battery includes charge-level detection and low-voltage prompts. The listed battery life is up to 6 hours.

Explosion-proof marking listed

The reference gives Ex ib IIC T3 Gb and describes Zone 1/2 applications; verify project approval and marking before use.

APPLICATIONS

Typical applications

Hydrogen-cooled generators

Carry out hydrogen leak checks around generator units and related equipment.

Hydrogen production stations

Support routine field inspections at hydrogen production facilities.

Hydrogen transmission pipelines

Locate potential leak points during pipeline inspection and maintenance.

Hazardous-area inspection

Review suitability for the specified site classification using the product marking and applicable local rules.

Portable Hydrogen Leak Detector technical specifications and integration requirements

ParameterSpecification
ModelNA-1⁺
Target gasHydrogen (H₂)
Measuring ranges0–1000 ppm; 0.1–4% Vol
Measurement methodPump suction, 200 mL/min flow rate
Warm-up time<60 s
Response time<2 s
Resolution1 ppm
Measurement error30% (0–1000 ppm); ±5% F.S. (0.1–4% Vol)
Power supplyRechargeable lithium-ion battery, 3.6–4.2 V
Battery life≤6 h
Explosion-proof markingEx ib IIC T3 Gb
Applicable classification listed by manufacturerZone 1 and Zone 2; gas groups IIA–IIC; temperature classes T1–T3
Charger input100–240 VAC, 50/60 Hz, 0.2 A
Charger output5.0 V, 400 mA
Dimensions169 × 60 × 28 mm (L × W × H)
Weight400 g

Confirm the measuring range, output, power supply, and process conditions for your application when requesting a quotation.

What to include in your inquiry

For a project-specific Portable Hydrogen Leak Detector quotation and application review, share your target measurement range, gas composition, operating temperature and humidity, pressure, installation method, required signal output, and project location. This helps our team assess the right configuration for your hydrogen monitoring or gas analysis system.

Send your application details

FAQ

Frequently asked questions about Portable Hydrogen Leak Detector selection and applications

Find guidance on Portable Hydrogen Leak Detector measuring range, installation, operating conditions, and integration with hydrogen monitoring systems.

01

What ranges does the NA-1⁺ portable hydrogen leak detector measure?

The listed dual ranges are 0–1000 ppm and 0.1–4% Vol, with automatic switching between the two sensors.

02

How is the gas sample collected?

The instrument uses pump-suction sampling at a specified flow rate of 200 mL/min.

03

How quickly does the detector respond?

The reference specifies a response time under 2 seconds and a warm-up time under 60 seconds.

04

What does the explosion-proof marking indicate?

The reference lists Ex ib IIC T3 Gb and describes Zone 1/2 usage. Confirm certificate scope, local approvals and site classification before deployment.

05

What should I include in a quotation request?

Share your application, target concentration range, sample access, site classification, operating conditions, expected inspection duration and destination country.

Discuss Portable Hydrogen Leak Detector for your application

Send your operating conditions and project requirements for a technical review and quotation.

Contact the Sales Team