Electrochemical oxygen measurement
Measures oxygen content in a hydrogen stream over the published 0–2% O₂ range.
ONLINE OXYGEN ANALYZER FOR HYDROGEN
Electrochemical O₂ measurement•Intrinsically safe probe•4–20 mA output•Two programmable alarms
Measurement range0–2% O₂
Accuracy / repeatability±0.03% / ±0.01%
Response time20 s
Analog output4–20 mA; max load 800 Ω
Alarm output2 independently programmable outputs; DC 24 V, 1 A
ProtectionNEMA 4X / IP66; Ex ia IIC T6 Ga
HOW THE PRODUCT WORKS
The RA1630 Online Oxygen-in-Hydrogen Analyzer is designed to measure oxygen content in hydrogen production stations, power plants, and industrial process gas. It uses an electrochemical oxygen sensor and an intrinsically safe probe to provide online measurement for applications where oxygen concentration in a hydrogen stream needs to be monitored.
The specified measuring range is 0–2% O₂, with ±0.03% accuracy, ±0.01% repeatability, and a 20-second response time. The analyzer provides a 4–20 mA analog output and two independently programmable alarm outputs. This allows measurement and alarm signals to be connected to a plant monitoring or control system; confirm the required scaling and alarm setpoints for your process.
The control unit is panel-mounted in a cabinet, with a specified cutout of 92 × 92 mm. The sampling system is wall-mounted on site and measures 600 × 450 × 120 mm. Product information describes a special acid/base pretreatment sampling system for complex samples. Review the actual sample chemistry and pretreatment requirements before specifying the installation.
The published operating temperature is −10 to +40 °C, enclosure protection is NEMA 4X / IP66, and the explosion-protection marking is Ex ia IIC T6 Ga. Confirm the hazardous-area classification, certificate requirements, sample composition, and panel and wall mounting locations as part of project engineering.
For a technical review and quotation, share the hydrogen source, expected oxygen range, sample composition and corrosive components, sampling arrangement, alarm setpoints, output requirements, installation location, and quantity. This supports a suitable online oxygen-in-hydrogen analyzer configuration for station and process monitoring.
Measures oxygen content in a hydrogen stream over the published 0–2% O₂ range.
The probe uses an intrinsically safe design; verify that the stated Ex ia IIC T6 Ga marking matches the site classification and project certification requirements.
Provides a 4–20 mA analog output and two independently programmable alarm outputs for system integration.
Product information describes a special acid/base pretreatment sampling system. Confirm compatibility with the process gas and contaminants before configuration.
The control unit is panel-mounted, while the sampling system is wall-mounted on site, supporting a distributed installation layout.
The product description states resistance to weak acid and weak alkali corrosion; provide sample composition for application review.
APPLICATIONS
Monitor oxygen content in hydrogen streams as part of gas quality and process supervision.
Integrate online oxygen measurement and programmable alarms into hydrogen-related monitoring systems.
Apply to industrial processes that require oxygen measurement in hydrogen, subject to sample and pretreatment compatibility.
| Parameter | Specification |
|---|---|
| Target measurement | Oxygen (O₂) in hydrogen |
| Measurement principle | Electrochemical |
| Measurement range | 0–2% O₂ |
| Accuracy | ±0.03% |
| Repeatability | ±0.01% |
| Response time | 20 s |
| Analog output | 4–20 mA; maximum load 800 Ω |
| Alarm output | Two independently programmable outputs; DC 24 V, 1 A |
| Operating temperature | −10 to +40 °C |
| Enclosure protection | NEMA 4X / IP66 |
| Explosion-proof marking | Ex ia IIC T6 Ga |
| Control unit installation | Panel-mounted on control cabinet; cutout 92 × 92 mm |
| Sampling system installation | Wall-mounted on site; dimensions 600 × 450 × 120 mm |
| Sample pretreatment | Special acid/base pretreatment system stated for complex samples; confirm suitability against actual sample chemistry |
Confirm the measuring range, output, power supply, and process conditions for your application when requesting a quotation.
For a project-specific RA1630 Online Oxygen-in-Hydrogen Analyzer quotation and application review, share your target measurement range, gas composition, operating temperature and humidity, pressure, installation method, required signal output, and project location. This helps our team assess the right configuration for your hydrogen monitoring or gas analysis system.
Send your application detailsFAQ
Find guidance on RA1630 Online Oxygen-in-Hydrogen Analyzer measuring range, installation, operating conditions, and integration with hydrogen monitoring systems.
The RA1630 measures oxygen content in hydrogen. Its published range is 0–2% O₂.
The published accuracy is ±0.03%, repeatability is ±0.01%, and response time is 20 seconds.
The listed interfaces are 4–20 mA analog output and two independently programmable alarm outputs rated DC 24 V, 1 A. Confirm signal scaling and alarm setpoints for your control system.
The control unit is panel-mounted with a specified cabinet cutout of 92 × 92 mm. The sampling system is wall-mounted and measures 600 × 450 × 120 mm.
Product information describes a special acid/base pretreatment system and resistance of the probe to weak acid and alkali corrosion. Provide the actual sample composition so suitability can be reviewed.
Share the hydrogen source, expected oxygen range, sample composition, pressure and pretreatment needs, alarm and output requirements, installation locations, hazardous-area classification, and project quantity.
Send your operating conditions and project requirements for a technical review and quotation.