Integrated gas-quality monitoring
Combines online monitoring of hydrogen humidity, purity, and oxygen content, with residual-hydrogen monitoring described for generator maintenance safety.
GENERATOR HYDROGEN QUALITY ANALYZER
Purity, humidity, O₂ and residual H₂ monitoring•Integrated explosion-proof design•Oil filtration•Alarm and 4–20 mA output
Purity rangeH₂/Air: 90–100%; CO₂/H₂ and CO₂/Air: 0–100%
Humidity (dew point)−80 to +20 °C; ±2 °C
Oxygen (O₂)0–25%; ±1% F.S
Residual hydrogen0–4% Vol; ±1% F.S
Remote signal4–20 mA; alarm output
Explosion protectionPurity / humidity / O₂: Ex d IIB + H₂ T5 Gb
HOW THE PRODUCT WORKS
The RS301ON-III H2 Quality Analyzer is designed to monitor hydrogen cooling systems on generator sets. It brings together online measurement of hydrogen purity, dew point humidity, oxygen, and residual hydrogen, with alarm output and 4–20 mA remote transmission. This multi-parameter view can help operations teams assess gas quality and maintenance conditions from one analyzer platform.
Purity measurement uses micro-thermal conductivity for H₂/air, CO₂/H₂, and CO₂/air mixtures. Humidity dew point is measured by a resistance-capacitance method, oxygen by an electrochemical sensor, and residual hydrogen by catalytic combustion. Each channel has its own specified range, accuracy, and explosion-protection marking; review the technical table for the individual values.
The electrical section and sensing unit use an integrated explosion-proof design with explosion-proof operation buttons. An oil-filter device is specified to help protect the sensing unit from oil contamination. The explosion-proof unit can be installed independently or with a sampling frame. The product information also describes under-pressure purity and humidity measurement to reduce hydrogen loss associated with evacuation-based measurement.
Before specifying the analyzer, confirm which parameters are required, the generator gas mixtures, operating pressure, sample arrangement, alarm points, output integration, and hazardous-area classification. The purity and humidity channels are stated as Ex d IIB + H₂ T5 Gb; the residual-hydrogen channel is stated as Ex d IIC T6 Gb. Confirm the exact certificate and configuration for the installation site.
For a technical review and quotation, share the generator model, required measurement channels, hydrogen and carbon-dioxide mixtures, sample pressure, alarm and 4–20 mA requirements, mounting arrangement, and commissioning schedule. This supports selection of an H2 quality analyzer for continuous generator cooling-system monitoring.
Combines online monitoring of hydrogen humidity, purity, and oxygen content, with residual-hydrogen monitoring described for generator maintenance safety.
Uses micro-thermal conductivity for purity, resistance-capacitance for dew point humidity, electrochemical measurement for oxygen, and catalytic combustion for residual hydrogen.
An oil-filter device is specified to help prevent oil contamination of the sensing unit.
The electrical section and sensing unit use an integrated explosion-proof design, with explosion-proof buttons for operator interaction.
The product information describes measurement under pressure to reduce hydrogen waste associated with evacuation-based measurement.
The explosion-proof unit can be installed independently or together with a sampling frame; confirm the selected arrangement for your site.
APPLICATIONS
Monitor multiple hydrogen quality parameters during generator cooling-system operation.
Use purity, humidity, oxygen, and residual-hydrogen information to support operating decisions and maintenance planning.
Residual-hydrogen monitoring is specified to support safety during unit maintenance; follow the site maintenance procedure and safety requirements.
| Parameter | Specification |
|---|---|
| Purity measurement principle | Micro-thermal conductivity |
| Purity ranges | H₂/Air: 90–100%; CO₂/H₂: 0–100%; CO₂/Air: 0–100% |
| Purity maximum allowable error | ±2% F.S |
| Purity explosion-proof marking | Ex d IIB + H₂ T5 Gb |
| Humidity (dew point) principle | Resistance-capacitance |
| Humidity (dew point) range | −80 to +20 °C |
| Humidity maximum allowable error | ±2 °C |
| Humidity explosion-proof marking | Ex d IIB + H₂ T5 Gb |
| Oxygen (O₂) principle | Electrochemical |
| Oxygen (O₂) range | 0–25% |
| Oxygen maximum allowable error | ±1% F.S |
| Oxygen explosion-proof marking | Ex d IIB + H₂ T5 Gb |
| Residual hydrogen principle | Catalytic combustion |
| Residual hydrogen range | 0–4% Vol |
| Residual hydrogen maximum allowable error | ±1% F.S |
| Residual hydrogen explosion-proof marking | Ex d IIC T6 Gb |
| Signal functions | Alarm output and 4–20 mA remote transmission |
| Construction | Integrated explosion-proof electrical section and sensing unit; oil-filter device |
| Installation options | Explosion-proof unit can be installed independently or with a sampling frame |
Confirm the measuring range, output, power supply, and process conditions for your application when requesting a quotation.
For a project-specific RS301ON-III H2 Quality Analyzer quotation and application review, share your target measurement range, gas composition, operating temperature and humidity, pressure, installation method, required signal output, and project location. This helps our team assess the right configuration for your hydrogen monitoring or gas analysis system.
Send your application detailsFAQ
Find guidance on RS301ON-III H2 Quality Analyzer measuring range, installation, operating conditions, and integration with hydrogen monitoring systems.
The product information describes online monitoring of hydrogen purity, dew point humidity, and oxygen content, and lists a residual-hydrogen channel for maintenance safety. Review the channel-specific ranges and required configuration before ordering.
The published ranges are H₂/Air at 90–100%, CO₂/H₂ at 0–100%, and CO₂/Air at 0–100%, with a maximum allowable error of ±2% F.S.
Humidity dew point is −80 to +20 °C with ±2 °C maximum error; oxygen is 0–25% with ±1% F.S; residual hydrogen is 0–4% Vol with ±1% F.S. Check the individual channel explosion-proof markings in the specification table.
The published product description lists alarm output and 4–20 mA remote transmission. Confirm channel mapping, alarm configuration, wiring, and interface requirements for the control system.
The explosion-proof unit can be installed independently or with a sampling frame. Confirm installation location, sampling arrangement, process pressure, and site classification with the technical team.
Provide generator model, measurement channels, gas mixtures, sample pressure, output and alarm needs, mounting arrangement, hazardous-area classification, and commissioning requirements.
Send your operating conditions and project requirements for a technical review and quotation.