RD3000E Gas Leakage Detection Alarm Controller product image

1–16 CHANNEL GAS DETECTION ALARM CONTROLLER

RD3000E Gas Leakage Detection Alarm Controller

1–16 detector channels•4–20 mA and RS-485 inputs•Audible/visual alarms•Ethernet and relay outputs

Supported channels1–16 compatible detectors

Signal inputsThree-wire 4–20 mA and RS-485 bus detectors

Alarm modesLow, high, and fault alarms

Signal outputsSwitch value, RS-485, Ethernet

Relay outputs2 dry normally-open groups; 10 A at 250 VAC

Main power85–265 VAC, 50/60 Hz

HOW THE PRODUCT WORKS

Centralized multi-point gas detection and alarm control for industrial sites

Multi-channel gas alarm control for industrial safety systems

The RD3000E Gas Leakage Detection Alarm Controller centralizes signals from compatible gas detectors across industrial sites. It supports 1–16 detection channels, accepting three-wire 4–20 mA detectors and RS-485 bus-type detectors, and can upload RS-485 communication data to host software. Depending on the selected detectors, the system can monitor combustible gases, toxic and harmful gases, temperature, and humidity.

Monitor multiple points and identify alarm conditions

A large LCD displays live concentration readings, and users can adjust high and low alarm setpoints. The controller provides low alarm, high alarm, and fault alarm modes. When a configured reading reaches its alarm condition, the controller issues audible and visual alarms and can drive exhaust ventilation or other connected equipment through relay outputs. Detector selection and setpoints must be matched to the target gas and site requirements.

Connect detector signals and control-room systems

The RD3000E accepts three-wire 4–20 mA analog inputs and RS-485 bus-type detectors. Its listed outputs include switch signals, RS-485, and Ethernet. Two groups of dry normally-open relay contacts are specified, rated 10 A at 250 VAC. Confirm compatible detector models, communication protocol, channel allocation, relay loads, and host software interface before system integration.

Alarm history, backup power, and wall mounting

The controller automatically stores at least 10,000 alarm records and uses two-level password management. Main supply is 85–265 VAC, 50/60 Hz; an optional backup supply uses two rechargeable 12 V / 7.2 Ah lead-acid batteries. The wall-mounted enclosure measures 500 × 360 × 122 mm and weighs about 15 kg. Verify environmental limits, mounting clearances, cable routes, and certification documents for the supplied configuration.

For a system quotation, provide the site type, target gases, detector models and quantity, 4–20 mA or RS-485 interfaces, alarm setpoints, relay-driven equipment, Ethernet or host software needs, backup power requirement, and installation environment. This helps match the multi-channel gas detection alarm controller to compatible detector signals and site alarm requirements.

Key product features

Expandable 1–16 detector channels

Modular controller design accepts 1–16 compatible detectors using three-wire 4–20 mA input or RS-485 bus communication.

Live readings with adjustable alarm setpoints

The large LCD displays live concentration values; high and low alarm setpoints can be adjusted for compatible detector and target gas configurations.

Audible/visual alarms and relay control

Low, high, and fault conditions can trigger audible and visual alarms. Two normally-open dry contact groups are provided for configured external equipment.

RS-485 and Ethernet connectivity

The controller supports RS-485 and Ethernet outputs, including upload of RS-485 detector communication data to host software; confirm protocol and software compatibility.

Alarm history and controlled access

Automatically stores at least 10,000 alarm records and provides two-level password management.

Optional backup supply

Main power operates from 85–265 VAC; an optional backup arrangement uses two 12 V / 7.2 Ah rechargeable lead-acid batteries.

APPLICATIONS

Typical applications

Hydrogen refuelling and production sites

Centralize compatible gas detector signals and alarms across hydrogen station or production facility detection points.

Chemical plants and oil refineries

Monitor configured combustible and toxic gas detection points and route alarms to ventilation or other equipment.

Fuel and gas filling stations

Connect multiple detectors for centralized readings and low/high alarm handling, subject to site design and detector compatibility.

Paint spray booths and industrial plants

Use multi-channel alarm control where industrial risk assessment calls for gas leak monitoring and control-room reporting.

RD3000E Gas Leakage Detection Alarm Controller technical specifications and integration requirements

ParameterSpecification
ModelRD3000E
Supported detector channels1–16 channels
Signal inputThree-wire 4–20 mA analog detectors and RS-485 bus-type detectors
Maximum permissible error±5% F.S
Alarm modesLow alarm, high alarm, fault alarm
Signal outputsSwitch value, RS-485 bus, Ethernet
Relay output2 groups of dry normally-open contacts; 10 A at 250 VAC
Display and alarm settingsLarge LCD; live concentration display; adjustable high and low alarm setpoints
Alarm record storageAt least 10,000 records
Access controlTwo-level password management
Main power supply85–265 VAC, 50/60 Hz
Optional backup power2 × 12 V / 7.2 Ah rechargeable lead-acid batteries
Power consumption45 W, excluding detectors
Operating temperature−10 to +55 °C
Operating humidity≤95% RH; confirm condensation conditions for supplied configuration
MountingWall-mounted
Dimensions (L × W × H)500 × 360 × 122 mm
WeightAbout 15 kg
Certifications stated in product documentationExplosion-proof, CCCF fire certification, and CE; verify certificates applicable to the supplied configuration

Confirm the measuring range, output, power supply, and process conditions for your application when requesting a quotation.

What to include in your inquiry

For a project-specific RD3000E Gas Leakage Detection Alarm Controller quotation and application review, share your target measurement range, gas composition, operating temperature and humidity, pressure, installation method, required signal output, and project location. This helps our team assess the right configuration for your hydrogen monitoring or gas analysis system.

Send your application details

FAQ

Frequently asked questions about RD3000E Gas Leakage Detection Alarm Controller selection and applications

Find guidance on RD3000E Gas Leakage Detection Alarm Controller measuring range, installation, operating conditions, and integration with hydrogen monitoring systems.

01

How many detectors can the RD3000E support?

The published configuration supports 1–16 detector channels. Confirm the number and type of input modules required for the project.

02

Which detector signal types are accepted?

The controller accepts three-wire 4–20 mA analog detectors and RS-485 bus-type detectors. Confirm the supported detector models and communication protocol.

03

What alarms and outputs are available?

The listed alarm modes are low, high, and fault alarms. Outputs include switch value, RS-485, Ethernet, and two groups of dry normally-open relay contacts rated 10 A at 250 VAC.

04

Can the controller start ventilation equipment?

The product documentation states that alarm outputs can drive exhaust ventilation and other equipment. Verify the connected load, relay arrangement, and safety interlocks with the system designer.

05

Is backup power available?

An optional backup supply is specified as two rechargeable 12 V / 7.2 Ah lead-acid batteries. Confirm backup runtime and configuration with the supplier.

06

What details should I provide for a quotation?

Share target gases, detector models and quantity, channel signals, alarm setpoints, relay loads, host software and Ethernet needs, backup supply, site environment, and required certification documents.

Discuss RD3000E Gas Leakage Detection Alarm Controller for your application

Send your operating conditions and project requirements for a technical review and quotation.

Contact the Sales Team