Automatic dual-range detection
Dual sensors switch automatically between 0–1000 ppm trace detection and the 0.1–4% Vol range.
PORTABLE HYDROGEN LEAK DETECTOR
Dual sensors and dual ranges•Automatic range switching•Pump sampling•Audible and visual alarms
Measuring ranges0–1000 ppm / 0.1–4% Vol
Measurement methodPump suction, 200 mL/min
Response time<2 s
Resolution1 ppm
Measurement error30% (ppm range); ±5% F.S. (vol% range)
Explosion-proof markingEx ib IIC T3 Gb
HOW THE PRODUCT WORKS
The NA-1⁺ Portable Hydrogen Leak Detector is a handheld instrument for locating hydrogen leaks during field inspections. Its dual-sensor design automatically switches between a trace-gas range of 0–1000 ppm and a higher range of 0.1–4% Vol, helping operators assess both low-level leaks and higher concentrations with one portable detector.
The instrument uses pump suction at a specified flow rate of 200 mL/min. It provides a digital reading, stores measurement parameters and triggers an alarm when the measured concentration reaches a preset limit. Typical applications include leak checks on hydrogen-cooled generators, hydrogen production stations and hydrogen transmission pipelines.
Before requesting a quotation, share the expected concentration range, sampling access, site classification, application and operating conditions. The reference lists explosion-proof marking Ex ib IIC T3 Gb; confirm the instrument marking, certificate scope and suitability against the hazardous-area classification and local requirements for each project.
These checks help select a portable hydrogen leak detector for field inspection in industrial and energy applications.
Dual sensors switch automatically between 0–1000 ppm trace detection and the 0.1–4% Vol range.
A specified sample flow of 200 mL/min supports active gas sampling during leak inspections.
The reference specifies response below 2 seconds and includes automatic zero correction, peak detection, data hold and fast zero return.
A segment LCD displays readings; threshold LEDs indicate 10 ppm, 100 ppm, 1000 ppm and 1% Vol. Sound and light alarms can be manually silenced.
The lithium-ion battery includes charge-level detection and low-voltage prompts. The listed battery life is up to 6 hours.
The reference gives Ex ib IIC T3 Gb and describes Zone 1/2 applications; verify project approval and marking before use.
APPLICATIONS
Carry out hydrogen leak checks around generator units and related equipment.
Support routine field inspections at hydrogen production facilities.
Locate potential leak points during pipeline inspection and maintenance.
Review suitability for the specified site classification using the product marking and applicable local rules.
| Parameter | Specification |
|---|---|
| Model | NA-1⁺ |
| Target gas | Hydrogen (H₂) |
| Measuring ranges | 0–1000 ppm; 0.1–4% Vol |
| Measurement method | Pump suction, 200 mL/min flow rate |
| Warm-up time | <60 s |
| Response time | <2 s |
| Resolution | 1 ppm |
| Measurement error | 30% (0–1000 ppm); ±5% F.S. (0.1–4% Vol) |
| Power supply | Rechargeable lithium-ion battery, 3.6–4.2 V |
| Battery life | ≤6 h |
| Explosion-proof marking | Ex ib IIC T3 Gb |
| Applicable classification listed by manufacturer | Zone 1 and Zone 2; gas groups IIA–IIC; temperature classes T1–T3 |
| Charger input | 100–240 VAC, 50/60 Hz, 0.2 A |
| Charger output | 5.0 V, 400 mA |
| Dimensions | 169 × 60 × 28 mm (L × W × H) |
| Weight | 400 g |
Confirm the measuring range, output, power supply, and process conditions for your application when requesting a quotation.
For a project-specific Portable Hydrogen Leak Detector quotation and application review, share your target measurement range, gas composition, operating temperature and humidity, pressure, installation method, required signal output, and project location. This helps our team assess the right configuration for your hydrogen monitoring or gas analysis system.
Send your application detailsFAQ
Find guidance on Portable Hydrogen Leak Detector measuring range, installation, operating conditions, and integration with hydrogen monitoring systems.
The listed dual ranges are 0–1000 ppm and 0.1–4% Vol, with automatic switching between the two sensors.
The instrument uses pump-suction sampling at a specified flow rate of 200 mL/min.
The reference specifies a response time under 2 seconds and a warm-up time under 60 seconds.
The reference lists Ex ib IIC T3 Gb and describes Zone 1/2 usage. Confirm certificate scope, local approvals and site classification before deployment.
Share your application, target concentration range, sample access, site classification, operating conditions, expected inspection duration and destination country.
Send your operating conditions and project requirements for a technical review and quotation.
Contact the Sales Team